How to calculate the power consumption of the electric boiler?
The electric boiler uses electric energy as the energy source, uses electric resistance or electromagnetic induction to drive the heat, and when the heat medium of the boiler heats the heat medium water to a certain parameter (temperature, pressure), the external output has the rated working medium (steam or hot water). A thermal mechanical device that meets the needs of industrial manufacturing, production and life.
Power consumption is an important indicator for assessing the overall quality of gas boilers. It is also one of the standards that users measure when purchasing boilers. This data will affect the input cost of the boiler operation; only the cost is controlled below a certain limit. In order to get more benefits.
How to calculate the power consumption of electric boilers?
We can remember the following sentence: The power consumption of a 1KW electric boiler operating at full load for 1 hour is 1 degree. The 1 ton electric boiler is about 0.7 MW, which is 700 KW. The power consumption of a 1 ton electric boiler operating at full load for 1 hour is 700 degrees.
However, it should also be noted that this is the power consumption situation of the electric boiler under full load; compared with other types of boilers, the electric boiler is more intelligent and can adjust steam or hot water according to different needs of users. The temperature of the boiler will change. In general, the average power consumption of the electric boiler is about 1/3-1/2 of the full load.
How to reduce the power consumption of electric boilers?
The method of reducing the power consumption of electric boilers mainly starts from the above four factors that affect the power consumption of the boiler.
1. Maintain good insulation effect in the boiler room
The heat insulation measures in the boiler room are properly handled. The heat loss during the operation of the electric boiler will decrease, and the heat energy utilization rate will increase, so that more power is not needed to meet the needs of users.
2. Changes in the heating environment
For houses that require heating, the height of the house and the configuration of the heating facilities must be handled properly to meet the optimal heating environment. The heat generated by the boiler operation is directly delivered to the house, reducing heat loss and reducing the power consumption of the boiler.
3. The situation of the electric boiler itself
The electric boiler itself must have a certain degree of intelligent regulation and control. According to the user's needs or changes in the environment, the working load in the boiler can be adjusted by itself, and the operating load can be increased when the demand temperature is high, and the operating load can be reduced when the demand temperature is low. Can alleviate the power consumption of the boiler.