Gas(oil) Fired Integrated Steam Boiler

Gas(oil) Fired Integrated Steam Boiler

  • Rated thermal power: 1-20t/h
  • Rated thermal efficiency: 100-104%
  • Pressure: ≤3.82MPa
  • Available fuel: heavy oil, diesel, natural gas, city gas, etc.
Get a quote

The series of boilers adopts an excellent design concept. Through the condensing device, the heat of the flue gas is used in cascade, and the residual heat in the flue gas is fully absorbed, so that the boiler efficiency is greatly improved.

Get a quote

LOW NITROGEN ENVIRONMENTAL PROTECTION BOILER, BUILT FOR 20 YEARS

  • High thermal efficiency

    The flue gas is heat exchanged through the spiral finned tube in the condenser and economizer, so the heat transfer effect is stronger, the fuel consumption is reduced by at least 4%, and the thermal efficiency is increased to 104%.

  • Perfect insulation measures

    Ultra-fine glass wool is used as insulation material between the smoke box and the tube sheet, and the heat loss is extremely small, reducing unnecessary heat waste.

  • Long service life

    The boiler body is made of a more corrosion-resistant material such as silicon-aluminum alloy. The combustion chamber is completely immersed in water and is not affected by high-temperature flue gas. So, the operating environment of the boiler is guaranteed.

  • High safety factor

    Various protection systems can prevent problems such as excessive water level, unstable pressure, abnormal power supply, scale detection, and so on, to ensure the safety of boiler operation.

TECHNOLOGY&PROCESS

Scale online warning

Once there is a situation that causes damage to boiler efficiency and performance, high-sensitivity scale detection system will immediately activate an early warning device to remind users to deal with it in time.

Frequency conversion water supply

According to the actual operation demand of the boiler, the dynamic water supply system can automatically adjust the water supply, realize the dynamic balance of the boiler and avoid wasting resources.

NC cutting

Cut edge

Intelligent welding

Drilling and reaming

Gas(oil) Fired Integrated Steam Boiler

Types Evaporation Steam pressure Steam temperature Feed water temperature Thermal efficiency Fuel Power requirement Length * Width * Height Weight Chimney
Unit t/h MPa °C °C % V/Hz mm t mm
WNS1-1.0-Y.Q 1 ≤3.82MPa (184)
194
(204)
20 100-104 Diesel,
heavy oil,
natural gas,
city gas
380/50 3650 * 2320 * 2970 5.1 300
WNS2-1.25-Y.Q 2 4650 * 2920 * 3640 9.3 350
WNS3-1.25-Y.Q 3 5340 * 2990 * 3860 11.8 450
WNS4-1.25-Y.Q 4 6170 * 2930 * 4170 12.9 450
WNS6-1.25-Y.Q 6 6760 * 3160 * 4390 16.3 550
WNS8-1.25-Y.Q 8 7720 * 3710 * 5210 24.1 700
WNS10-1.25-Y.Q 10 7940 * 3770 * 5210 25.5 700
WNS15-1.25-Y.Q 15 9300 * 5390 * 5490 36.2 900
WNS20-1.25-Y.Q 20 9500 * 5770 * 5930 47.4 900

SCIENTIFIC RESEARCH STRENGTH