Model |
Unite |
SZS10-1.6 /350-Y(Q) |
SZS15-1.6 /350-Y(Q) |
SZS20-2.5 /400-Y(Q) |
SZS25-2.5 /400-Y(Q) |
SZS30-2.5 /400-Y(Q) |
SZS35-2.5 /400-Y(Q) |
SZS40-2.5 /400-Y(Q) |
Rated evaporation |
t/h |
10 |
15 |
20 |
25 |
30 |
35 |
40 |
Electric power of water supply pump |
kW |
18.5 |
37 |
55 |
90 |
90 |
90 |
110 |
Electric power of draught fan |
kW |
22 |
37 |
55 |
75 |
90 |
90 |
110 |
Gas supply pressure |
Natural gas |
mbar |
300 |
450 |
City gas |
mbar |
300 |
450 |
Liquefied petroleum gas |
mbar |
300 |
450 |
Fuel consumption |
Diesel oil |
kg/h |
711.8 |
1067.7 |
1475.4 |
1844.2 |
2213 |
2581.9 |
2950.7 |
Fuel-oil |
kg/h |
740 |
1109.9 |
1533.7 |
1917.1 |
2300.6 |
2684 |
3067.4 |
Natural gas |
Nm³/h |
752.2 |
1128.3 |
1559.1 |
1948.9 |
2338.6 |
2728.4 |
3118.2 |
City gas |
Nm³/h |
1527.8 |
2291.7 |
3166.7 |
3958.3 |
4750 |
5541.7 |
6333.3 |
Liquefied petroleum gas |
Nm³/h |
275 |
412.5 |
570 |
712.6 |
855.1 |
997.6 |
1140.1 |
Rated steam pressure |
Mpa |
1.6 |
2.5 |
Rated superheated steam pressure |
℃ |
350 |
400 |
General |
Power supply |
V/Hz |
380/50 |
Combustion mode |
Mpa |
Micro positive chamber combustion |
Water supply temperature |
℃ |
20 |
Thermal efficiency |
% |
100-104 |
Combustion regulation mode |
Mpa |
Full automatic proportional regulation |
Smoke exhaust temperature |
℃ |
70-90 |
Model |
Unite |
SZS10-1.6-Y(Q) |
SZS15-1.6-Y(Q) |
SZS20-1.6-Y(Q) |
SZS25-1.6-Y(Q) |
SZS30-1.6-Y(Q) |
SZS40-1.6-Y(Q) |
SZS50-1.6-Y(Q) |
Rated evaporation |
t/h |
10 |
15 |
20 |
25 |
30 |
40 |
50 |
Electric power of water supply pump |
kW |
11 |
15 |
18.5 |
22 |
30 |
30 |
45 |
Electric power of draught fan |
kW |
22 |
37 |
55 |
75 |
90 |
110 |
132 |
Gas supply pressure |
Natural gas |
mbar |
300 |
450 |
City gas |
mbar |
300 |
450 |
Liquefied petroleum gas |
mbar |
300 |
450 |
Fuel consumption |
Diesel oil |
kg/h |
637.1 |
955.7 |
1274.3 |
1592.8 |
1911.4 |
2548.5 |
2789.7 |
Fuel-oil |
kg/h |
662.3 |
993.5 |
1324.7 |
1655.8 |
1987 |
2649.3 |
2649.3 |
Natural gas |
Nm³/h |
673.3 |
1009.9 |
1346.6 |
1683.2 |
2019.9 |
3121.7 |
3121.7 |
City gas |
Nm³/h |
1367.5 |
2051.3 |
2735 |
3418.8 |
4102.6 |
5470.1 |
5470.1 |
Liquefied petroleum gas |
Nm³/h |
246.2 |
369.3 |
492.3 |
615.4 |
738.5 |
984.7 |
984.7 |
General |
Rated steam pressure |
MPa |
1.6 |
Thermal efficiency |
% |
100-104 |
Rated saturated steam temperature |
℃ |
204 |
Power supply |
v/Hz |
380/50 |
Combustion mode |
MPa |
Micro positive chamber combustion |
Water supply temperature |
℃ |
20 |
Steam supply port |
DN |
According to the pressure of gas supply |
Combustion regulation mode |
MPa |
Full automatic proportional regulation |
Smoke exhaust temperature |
℃ |
60-90 |
Model |
Unit |
SZS10.5-1.25 /130/70-Y(Q) |
SZS14-1.25 /130/70-Y(Q) |
SZS17.5-1.6 /130/70-Y(Q) |
SZS21-1.6 /130/70-Y(Q) |
SZS24.5-1.6 /130/70-Y(Q) |
SZS29-1.6 /130/70-Y(Q) |
SZS46-1.6 /130/70-Y(Q) |
SZS58-1.6 /130/70-Y(Q) |
SZS70-1.6 /130/70-Y(Q) |
Stable thermal power |
MW |
10.5 |
14 |
17.5 |
21 |
24.5 |
29 |
46 |
58 |
70 |
Rated water-outlet pressure |
MPa |
1.25 |
1.25 |
1.6 |
1.6 |
1.6 |
1.6 |
1.6 |
1.6 |
1.6 |
Gas supply pressure |
Natural gas |
mbar |
300 |
450 |
500 |
City gas |
mbar |
300 |
450 |
500 |
Liquefied petroleum gas |
mbar |
300 |
450 |
500 |
Fuel consumption |
Diesel oil |
kg/h |
914.5 |
1245.5 |
1531.87 |
1880.55 |
2134.1 |
2522.8 |
3934.3 |
5028.7 |
5980.8 |
Fuel-oil |
kg/h |
950.8 |
1267.7 |
1584.7 |
1901.6 |
2218.6 |
2641.1 |
4157.3 |
5236.5 |
6319.9 |
Natural gas |
Nm³/h |
1004.8 |
1388.3 |
1712.69 |
2115.96 |
2344.5 |
2825.3 |
4412.1 |
5672.7 |
7065 |
City gas |
Nm³/h |
2040.8 |
2721.1 |
3401.4 |
4081.6 |
4761.9 |
5668.9 |
10081.5 |
12698.6 |
15325.9 |
Liquefied petroleum gas |
Nm³/h |
367.4 |
489.8 |
612.3 |
734.8 |
857.2 |
1020.5 |
3934.3 |
4955.5 |
5980.8 |
General |
Rated water-outlet temperature |
℃ |
130 |
Thermal efficiency |
% |
95-98 |
Combustion mode |
MPa |
Micro positive chamber combustion |
Rated water-inlet temperature |
℃ |
70 |
Power supply |
V/Hz |
380/50 |
Combustion regulation mode |
MPa |
Full automatic proportional regulation |
∗Take 38.3MJ/Nm³ as the low calorific value of natural gas
∗As the technology is constantly updated, it is subject to change without notice. For detailed parameters, please refer to the headquarters of Fangkuai Boiler co., LTD.